Paramagnetic relaxation: PRE and paramagnetic CCR
Measure the relaxation a paramagnetic centre adds, from a diamagnetic and a paramagnetic sample, and fit the tensor to it.
A paramagnetic centre enhances the relaxation of nearby nuclei, and the extra rate falls away steeply with distance — which makes it one of the few NMR observables that reaches tens of ångströms and reports on sparsely populated, transient contacts that NOEs miss. The measurement is a difference between two samples, which is why it is easy to do badly: any processing or picking difference between them reads as structure.
These pipelines measure both samples the same way. A diamagnetic and a paramagnetic series are picked and fitted with the same settings, the rate each adds is computed per residue, and the result is carried straight into a paramagpy fit of the tensor against your structure. You can enter from spectra, from a peak list or from fitted intensities, and the fit that results is the same one the tensor-fitting task would run on a rate list you already had.
The cross-correlated variant does the same with η. The cross-correlated rate of each sample — diamagnetic and paramagnetic, each measured from its own component spectra — is fitted, and the tensor is fitted to the pair. Because η is far less sensitive to chemical exchange than R2, it is the safer route where exchange broadening would contaminate a conventional PRE.
What it needs
- Diamagnetic and paramagnetic spectra, peak lists or fitted intensities
- For paramagnetic CCR, each sample's cross-correlated component spectra
- Structure with the metal site, and a starting tensor
What you get
- Per-residue rate added by the paramagnetic centre
- Δχ tensor fitted to it
- Back-calculated rates and residuals
Enter wherever your data already is
This analysis runs as a full pipeline from spectra, or picks up from work you have already done — so nothing has to be repeated to get to the next step.
- From spectra
- From a peak list
- From fitted intensities
What does the work
ParaMagPy
Open source, redistributed under its licenceGPL-3.0Tensor fitting to PRE and CCR rates
Cadence
Built in-houseRate and η analysis
Related in RDC & paramagnetic
- RDC measurementExtract residual dipolar couplings from intensity-based experiments on a weakly aligned sample.
- PCS matching and assignment transferFit the Δχ tensor from a diamagnetic/paramagnetic peak-list pair and transfer assignments onto the paramagnetic spectrum.
- Paramagnetic tensor fittingFit Δχ tensors to PCS and paramagnetic RDC data against a known structure.