Skip to content

Relaxation & dynamics

Dynamics detectors

Resolve motion into windows of timescale from any combination of relaxation experiments, without choosing a motional model first.

Model-free analysis asks you to decide what kind of motion a residue undergoes before it will tell you how much. The detectors framework inverts that: it combines whatever relaxation data you have into a small set of detector responses, each sensitive to a window of correlation times, and reports how much motion falls in each window. No model has to be selected, so no model selection can bias the answer.

The inputs are not fixed to the classic triple. R1, R2, R1ρ, the heteronuclear NOE, cross-correlated rates and σ are all accepted, at any combination of fields, and the number of windows you can separate grows with the experiments you bring. An R1, R2 and NOE at one field supports the fewest; adding a second field or a CCR rate buys another. The sensitivity of each detector is plotted next to its result, so you can see which timescales it actually covers rather than taking the labels on trust.

Each experiment can be measured from its own spectra — as the relaxation, NOE and cross-correlated pipelines measure theirs — or brought as rates you have already fitted, and the result is filed in the same place either way. Run it alongside a model-free fit: where the two disagree, the model is the likelier culprit.

What it needs

  • Any of R1, R2, R1ρ, heteronuclear NOE, cross-correlated rates or σ, at one or more fields
  • As spectra, a peak list, fitted intensities or rates you already have
  • Overall correlation time

What you get

  • Detector responses per residue with uncertainties
  • Detector sensitivity curves
  • The rates each experiment contributed

Enter wherever your data already is

This analysis runs as a full pipeline from spectra, or picks up from work you have already done — so nothing has to be repeated to get to the next step.

  • From spectra
  • From a peak list
  • From fitted intensities
Enter a pipeline wherever your data already isA four-stage pipeline runs left to right: spectra, peak picking, peak fitting, rate fitting. Three labelled entry points feed in from below — full starts at spectra, from-picking starts at peak fitting, and from-fitting starts at rate fitting — so work already done elsewhere does not have to be repeated.SpectraPeak pickingPeak fittingRate fittingfullfrom-pickingfrom-fitting

What does the work

  • Cadence

    Built in-house

    Detector framework and rate kernel

  • pyDIFRATE

    Open source, redistributed under its licenceGPL-3.0

    Detector fitting

Related in Relaxation & dynamics