Relaxation & dynamics
LeMaster and IMPACT spectral density fits
Decompose relaxation into amplitudes at fixed timescales, per field with LeMaster or stacked across every field with IMPACT.
Both analyses start from the same place as reduced spectral density mapping — the values of J(ω) that R1, R2 and the NOE determine — but ask a different question of them: how much of the motion sits at each of a fixed set of timescales. That is a description of the dynamics you can compare between residues, and between molecules, without agreeing on a model.
LeMaster's fit decomposes one field's rates against a known overall correlation time, which you supply in nanoseconds because the decomposition is resolved against that tumbling and cannot estimate it. Each field is fitted independently, so a second field is a consistency check on the first.
IMPACT (Khan et al., Biophysical Journal 109:988, 2015) stacks every field you measured into one amplitude fit against a geometric series of correlation times, so the extra fields add constraints rather than only repeating the question. Both run from raw spectra, a peak list or fitted intensities; LeMaster also runs directly on stored rates.
What it needs
- R1, R2 and heteronuclear NOE at one field; further fields for IMPACT
- Overall correlation time, for LeMaster
- As spectra, a peak list, fitted intensities or stored rates
What you get
- Amplitudes at fixed timescales per residue
- Per-field fits (LeMaster) or one stacked fit (IMPACT)
Enter wherever your data already is
This analysis runs as a full pipeline from spectra, or picks up from work you have already done — so nothing has to be repeated to get to the next step.
- From spectra
- From a peak list
- From fitted intensities
What does the work
pyDIFRATE
Open source, redistributed under its licenceGPL-3.0LeMaster and IMPACT fitting
Related in Relaxation & dynamics
- R1 and R2 relaxation ratesFit per-residue longitudinal and transverse relaxation rates from a pseudo-3D delay series.
- Heteronuclear NOEMeasure the steady-state NOE from saturated and reference spectra — the most direct read on fast internal motion.
- Reduced spectral density mappingConvert R1, R2 and NOE into spectral densities at three frequencies, without assuming a motional model.
- Model-free analysisFit order parameters and internal correlation times, with model selection and a diffusion tensor that is estimated rather than assumed.